PE02 Low Flow Electromagnetic flow meters

PE02 Low Flow Electromagnetic flow meters

PE 102The PE102 magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4” to 1/4” pipe/tube. The housing is made of sturdy splashproof HDPE plastic.

 

With no moving parts, the PE102 flow meter can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the flow meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 microSiemens) of varying viscosities and densities.

 

FEATURES

 

  • No moving parts
  • Requires no straight pipe
  • Pulse and/or 4-20 mA output
  • Chemical and corrosion resistant
  • Insensitive to fluid density and fluid viscosity changes

 

APPLICATIONS

  • Chemical injection
  • Corrosive materials
  • Low flow applications
  • Pulsating flows (e.g., metering pump)

 

The PE flow meter is compact enough to fit most pump/injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability.

The PE flow meter has optocoupled current sinking or current sourcing pulse output that can be connected to the Seametrics FT420 rate/total display or FT520 batch processor, as well as a 4-20 mA loop for powering analog devices. Outputs and power are provided through a cable with 8-pin female circular connector.

 

SPECIFICATION

Pipe Size 3/4”, 1/2”, 3/8”, 1/4”**
Fittings FlareTek fittings standard in 3/4” or 3/8” flowbody; NPT threaded adapters also available
Materials                                         Body PVDF
                                                          Electrodes PVDF carbon fiber-filled
                                                          Ground PVDF carbon fiber-filled
                                                          Housing HDPE with glass fiber
                                                          Fittings (FlareTek) PVDF
                                                          Adapters (NPT) Polypropylene or PVDF
                                                         O-Rings (for NPT) EPDM or Viton
Temperature Ambient 0˚ to 130˚ F (-18˚ to 54˚ C)
Fluid 32˚ to 200˚ F (0˚ to 93˚ C)
Pressure 150 psi
Flow Range                                  -075 20 GPM Max. (0.2 GPM cut off)
                                                       -038 3 GPM Max. (0.03 GPM cut off)
Accuracy                                       -075 +/- 1% plus +/- 0.005 GPM of reading across rated range
                                                       -038 +/- 1% plus +/- 0.002 GPM of reading across rated range
Output Signal Optocoupled current sinking or current sourcing pulse output: 30 Vdc, 5 mA max

4-20 mA current loop: 7 Vdc plus load voltage drop min; 50 Vdc max

                                                       -075 PE102-075: 500 pulses/liter (1892 pulses/gallon),
                                                       -038 PE102-038: 1,000 pulses/liter (3785 pulses/gallon).
Power 10-15 Vdc, 150 mA (linear power supply recommended)
Conductivity >20 microSiemens
Empty Pipe Detection Hardware/software, conductivity-based
Environmental NEMA 4X standard; IP 66 Splashproof standard