Dual Chanel Ultrasonic meter
 Dual Chanel Ultrasonic meter
FEATURES
– Stratified fluid piping design for two-channel measurement, measurement accuracy
– Range than the width, and less than 0.01m / s starting flow
– Display large amount of information, with the screen display 9 digital display four cumulative flow and instantaneous flow figures
– Design of energy-saving, power-saving features such as automatic meter will empty tube or long-term fluid standstill
– Full IP68 protection class design, the components completely sealed to protect, even if the water can be long-term work
– Design at the time, there were a total of records and data collection functions on the month, day
– With multiple communication interface mode; TTL level pulse output and USART interface for easy connection to other low power devices; standard RS485 interface;
infrared communication interface; support CJ-188 communication protocol.
– Supports standard MODBUS, M-BUS, HART communication protocol, compatible communications protocol Haifeng ASCa code
– Output signal and diverse: Available two isolated pulse signal output, ( which pulse and pulse width equivalent programmable) ; may also 4-20mA two-wire output
– With online software upgrades
– With Dual PT1000 temperature measurement function, can achieve heat measurement
– Built-quantitative control can be achieved manually or set the time automatically start controller, thus achieving automatic timing quantitative or
quantitative irrigation water
– Depending on customer needs to select a variety of units, including cubic US gallons, cubic feet and liters
– Built-in lithium battery, the battery life of more than 6 years
SPECIFICATIONS
Project | Parameter |
Accuracy class | 2 (measurement period: 1 second) |
Turndown ratio | 100, initiating a flow rate of less than 0.006m / s |
Measurement Range | Water, sewage, water (and other liquids to be customized), and filled conduit |
Medium temp measurement | 0.1-30 ℃ |
Work Environment | Temperature: -10 ~ 45 ℃; humidity ≤ 100% (RH) |
Pressure Rating | 1.6MPa/2.5MPa optional |
Upstream flow field sensitivity level | U3 |
Downstream flow field sensitivity level | D0 |
Climatic and mechanical environmental safety class | C grade |
Electromagnetic Compatibility Level | E2 level |
Communication Interface | RS485/USART / IR / USART serial communication bus, etc. Optional |
The output signal | Two-wire 4-20mA analog outputs (OCT or two isolated TTL optional programmable pulse width) |
Communication protocol | Haifeng fully compatible protocol (individual command very differentiated) also supports the standard MODBUS, M-BUS, CJ-188 communication protocol |
Heat measurement | Access Dual PT1000 achieve heat measurement |
Power supply | Built-in lithium battery (3.6V) / External DC5 ~ 40V |
Protection class | IP68 |
Local Display | Two-line display includes nine accumulation, four instantaneous flow, as well as prompt and unit status |
Data Storage | Using EEPROM / FLASH to store data, cumulative flow automatically record 128 months ago, 512 days ago |
Flow measurement cycle | Measurement status: 1 times / sec (can also be set from 2 to 4 times / sec); verification status: 4 times / sec |
Power and Power | Built-in 3.6V lithium battery can be used continuously for more than six years, external DC8-36V |