Dual Chanel Ultrasonic meter

 Dual Chanel Ultrasonic meter

images

FEATURES

– Stratified fluid piping design for two-channel measurement, measurement accuracy

– Range than the width, and less than 0.01m / s starting flow

– Display large amount of information, with the screen display 9 digital display four cumulative flow and instantaneous flow figures

– Design of energy-saving, power-saving features such as automatic meter will empty tube or long-term fluid standstill

– Full IP68 protection class design, the components completely sealed to protect, even if the water can be long-term work

– Design at the time, there were a total of records and data collection functions on the month, day

– With multiple communication interface mode; TTL level pulse output and USART interface for easy connection to other low power devices; standard RS485 interface;

infrared communication interface; support CJ-188 communication protocol.

– Supports standard MODBUS, M-BUS, HART communication protocol, compatible communications protocol Haifeng ASCa code

– Output signal and diverse: Available two isolated pulse signal output, ( which pulse and pulse width equivalent programmable) ; may also 4-20mA two-wire output

– With online software upgrades

– With Dual PT1000 temperature measurement function, can achieve heat measurement

– Built-quantitative control can be achieved manually or set the time automatically start controller, thus achieving automatic timing quantitative or

quantitative irrigation water

– Depending on customer needs to select a variety of units, including cubic US gallons, cubic feet and liters

– Built-in lithium battery, the battery life of more than 6 years

 

SPECIFICATIONS

Project Parameter
Accuracy class 2 (measurement period: 1 second)
Turndown ratio 100, initiating a flow rate of less than 0.006m / s
Measurement Range Water, sewage, water (and other liquids to be customized), and filled conduit
Medium temp measurement 0.1-30 ℃
Work Environment Temperature: -10 ~ 45 ℃; humidity ≤ 100% (RH)
Pressure Rating 1.6MPa/2.5MPa optional
Upstream flow field sensitivity level U3
Downstream flow field sensitivity level D0
Climatic and mechanical environmental safety class C grade
Electromagnetic Compatibility Level E2 level
Communication Interface RS485/USART / IR / USART serial communication bus, etc. Optional
The output signal Two-wire 4-20mA analog outputs (OCT or two isolated TTL optional programmable pulse width)
Communication protocol Haifeng fully compatible protocol (individual command very differentiated) also supports the standard MODBUS, M-BUS, CJ-188 communication protocol
Heat measurement Access Dual PT1000 achieve heat measurement
Power supply Built-in lithium battery (3.6V) / External DC5 ~ 40V
Protection class IP68
Local Display Two-line display includes nine accumulation, four instantaneous flow, as well as prompt and unit status
Data Storage Using EEPROM / FLASH to store data, cumulative flow automatically record 128 months ago, 512 days ago
Flow measurement cycle Measurement status: 1 times / sec (can also be set from 2 to 4 times / sec); verification status: 4 times / sec
Power and Power Built-in 3.6V lithium battery can be used continuously for more than six years, external DC8-36V