WUF100 C Clamp On Ultrasonic Flow meter

Flowmasonic WUF100 C

WALL MOUNT ULTRASONIC FLOW METER

TECHNOLOGY FEATURES:
1:operating power :AC 85—264V or isolation DC 24V
2:current: 50mA(under the condition of connection without keyboard display and alarm of beeper)
3:signal output :one channel standard isolation RS485 output
  • One channel isolation 4-20mA or 0-20mA active output.
  • One channel OCT output(programmed between the pulse width(6-1000ms),default before leaving factory (200ms))
  • One channel isolation relay output,with positive,negative,net totaliser pulses and different alarm signals.
4:signal input: two channel three wire system PT100 platinum resistor input loop,to make heat meter      has the function of displaying heat quantity.
       Three channel 4-20mA input optional,accuracy:0.1%,has the ability to input the signals of                    pressure, liquid level, temperature and so on.
5::display:2*20 backlit LCD(Chinese and English optional)
6:operating:4*4 tactile keypad or magnetic 4 keypads operating(F4 mainframe)
7:other functions:automatic memory the positive,negative,net totaliser or flow rate and thermal              energy of the last 512 days,128 months,10years
         Automatic memory the time of power turning on and off and flow rate of the last 30 times,                  realize to compensate by hand or automatically read the datas through Modbus communication

protocol.

8:protection level:mainframe:IP65,IP68(F4 mainframe),transducer:IP:68
9:ex-proof:EXd two BT4(TDS-100F2 type)
10:transducer: clamp-on type ,insertion type ,in-line type.
OPTIONAL ACCESSORY:
1:clamp-on transducer(standard S1 style,standard M1 style,high temperature S1H,high temperature M1H)
2:insertion transducer(standard insertion B,cement insertion B)
3:in line type transducer(hygienic style, Π style,standard style)
4:PT100 3 wire system platinum resistor(one pair, used for heat meter)
5:SEYV75-2 style special shielded twisted pair cable
6:fixture(applied with installation of transducers on cast iron,GRP,PVC,etc. that can not be welded directly.
7:ultrasonic thickness gauge(measure the thickness of pipe, reduce error, increase accuracy)
CLAMP ON TRANSDUCER
A pair of clamp-on transducer to measure the flow from outside of a pipe, there is no pressure drop, no moving parts, no leaks and no contamination. The installation is very simple and no special skills or tools are required.